TESTS PERFORMED:
Cooling Mode:
- Verify proper electrical signature,
- Pressure and temperature ranges,
- Component operation,
- System performance, and
- Operating stages
Heating Mode (Heat Pump):
- Verify proper electrical signature,
- Pressure ranges,
- Temperature ranges,
- Component operation,
- Performance,
- Reversing valve operation, and
- Stages
Heating Mode (Electrical Heat):
- Verify proper electrical signature,
- Heater current draw or resistance,
- Temperature ranges,
- Component operation,
- Performance,
- Stages,
- Emergency backup call
Heating Mode (Gas Furnace):
- Verify proper electrical signature,
- Pressure ranges,
- Temperature ranges,
- Component operation,
- Performance,
- Burner stages,
- Gas flow,
- Inducer current draw,
- Inducer differential pressure,
- Flue operation,
- Ignition sequence,
- Low gas flow shut down
- Blocked flue shut down
Idle State:
- Verify proper electrical signature,
- Transformer operation
Defrost Board Operation:
- Verify fan shutdown and
- Heat strip operation
Dehumidification Test
- Verify proper electrical signature,
- Pressure ranges
- Temperature ranges,
- Component operation,
- Performance,
- Stages,
- Refrigeration line temperature
Vent Package Test:
- Verify proper electrical signature,
- Component operation,
- Stages,
- Filter operation
Low Voltage Start:
- Verify proper electrical signature at brown out conditions,
- Component operation
UL Safety Test:
- Hypot,
- Ground bond,
- Insulation,
- Continuity check,
- Contactor pull-in verification
Wire Test:
- Verify proper unit connections prior to testing
Windings Test:
- Verify that unit wiring is not cross phased and power leads are connected prior to applying voltage.
Low Ambient Controls:
- Verify delayed fan operation starting and shutting down.
MACHINE FEATURES:
Test Mode
Allows operator to apply voltage to unit and manipulate thermostat controls for troubleshooting purposes or to run pilot units to collect test values.
Service Mode
Allows Maintenance to operate and monitor individual components of the tester to verify operation, troubleshoot and perform PM.
Analog Sensor Calibration
Provides a simple means of verifying sensor operation and adjusting the readings to match a control source.
Station Performance Monitoring
Track testing results over an adjustable range including pass, fail, processed, first time yield, operator idle time, etc.
Operator Security
Insure only trained operators can operate the test station, track operator efficiency, prevent unauthorized and unsafe use.
Personalized Work Instructions and Messaging
Customize and adjust the work instructions to fit the nomenclature and culture of your work environment. You have complete control over wording, font, color and size.
Network and Remote Connectivity Monitoring and Troubleshooting
On screen notifications allow the operator to know if a problem has occured to the system connections.
Wireless Bar Code Readers Standard
Touchscreen Monitors Available
DIMENSIONS:
90″H x 134″W x 36″D
UTILITY REQUIREMENTS:
480V, 3Ø, 100A-200A